WES013 [1]
Description:
electrical resistivity monitoring
File upload:

Variables:
DataCode
- Label:
- Definition: Dataset Code
- Type: Nominal
- Missing values: None specified
RecType
- Label:
- Definition: Record type
- Type: Physical quantity
- Unit: dimensionless
- Maximum: Not specified
- Minimum: Not specified
- Precision: Not specified
- Missing values: None specified
Rainfall_stage
- Label:
- Definition: Rainfall stage (Background, FirstRain, SecondRain, ThirdRain, EndRain).
- Type: Code list
- Codes:
- Background = Background
- FirstRain = FirstRain
- SecondRain = SecondRain
- ThirdRain = ThirdRain
- EndRain = EndRain
- Missing values: None specified
Spa1
- Label:
- Definition: Number of the injection electrode A
- Type: Physical quantity
- Unit: number
- Maximum: Not specified
- Minimum: Not specified
- Precision: Not specified
- Missing values: None specified
Spa2
- Label:
- Definition: Number of the injection electrode B
- Type: Physical quantity
- Unit: number
- Maximum: Not specified
- Minimum: Not specified
- Precision: Not specified
- Missing values: None specified
Spa3
- Label:
- Definition: Number of the injection electrode M
- Type: Physical quantity
- Unit: number
- Maximum: Not specified
- Minimum: Not specified
- Precision: Not specified
- Missing values: None specified
Spa4
- Label:
- Definition: Number of the injection electrode N
- Type: Physical quantity
- Unit: number
- Maximum: Not specified
- Minimum: Not specified
- Precision: Not specified
- Missing values: None specified
Rho
- Label:
- Definition: apparent resistivity (ohmMeter)
- Type: Physical quantity
- Unit: ohmMeter
- Maximum: Not specified
- Minimum: Not specified
- Precision: Not specified
- Missing values: None specified
Dev_Rho
- Label:
- Definition: standard deviation of apparent resistivity
- Type: Physical quantity
- Unit: percent
- Maximum: Not specified
- Minimum: Not specified
- Precision: Not specified
- Missing values: None specified
SP
- Label:
- Definition: self-potential current measured before the injection (millivolt)
- Type: Physical quantity
- Unit: millivolt
- Maximum: Not specified
- Minimum: Not specified
- Precision: Not specified
- Missing values: None specified
VMN
- Label:
- Definition: measured potential between electrodes M and N (millivolt)
- Type: Physical quantity
- Unit: millivolt
- Maximum: Not specified
- Minimum: Not specified
- Precision: Not specified
- Missing values: None specified
IAB
- Label:
- Definition: injected current between electrodes A and B (milliamp)
- Type: Physical quantity
- Unit: milliamp (mA)
- Maximum: Not specified
- Minimum: Not specified
- Precision: Not specified
- Missing values: None specified
Time_dur
- Label:
- Definition: duration of measurement (millisecond)
- Type: Physical quantity
- Unit: millisecond
- Maximum: Not specified
- Minimum: Not specified
- Precision: Not specified
- Missing values: None specified
Coef
- Label:
- Definition: Coef (geometric coefficient calculated by the IRIS Syscal Pro, which does not consider the actual position of the electrodes)
- Type: Physical quantity
- Unit: meter
- Maximum: Not specified
- Minimum: Not specified
- Precision: Not specified
- Missing values: None specified
Stack
- Label:
- Definition: number of repeated measurements
- Type: Physical quantity
- Unit: number
- Maximum: Not specified
- Minimum: Not specified
- Precision: Not specified
- Missing values: None specified
Rs_check
- Label:
- Definition: contact resistance
- Type: Physical quantity
- Unit: ohmMeter
- Maximum: Not specified
- Minimum: Not specified
- Precision: Not specified
- Missing values: None specified
Vab
- Label:
- Definition: injected potential between electrodes A and B
- Type: Physical quantity
- Unit: volt
- Maximum: Not specified
- Minimum: Not specified
- Precision: Not specified
- Missing values: None specified
Date_m
- Label:
- Definition: date and time of measurement
- Type: Date/time
- Date format: YYYY-MM-DD HH:MM:SS
- Missing values: None specified
Number of records: